LEPRECHAUN 90 O.S.A
WOODBURNING STOVE
SAFETY NOTICE
Please read this entire manual before you install and use your new room heater. Failure to follow instructions
may result in property damage, bodily injury or even death.
This appliance is hot while in operation and retains its heat for a long period of time after use. Children,
aged or infirm persons should be supervised at all times and should not be allowed to touch the hot
working surfaces while in use or until the appliance has thoroughly cooled.
If this stove is not properly installed, a house fire may result. For your safety, follow the installation directions.
Contact local building or fire officials about restrictions and installation inspection requirements in your area.
The stove must be connected to a UL/ULC listed high temperature residential type H.T. and building heating
appliance chimney or an approved masonry chimney with flue liner.
INSTALLATION AND OPERATING INSTRUCTIONS
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - WOODBURNING STOVE

LEPRECHAUN 90 O.S.AWOODBURNING STOVESAFETY NOTICEPlease read this entire manual before you install and use your new room heater. Failure to follow in

Page 2 - Leprechaun 90 O.S.A

has caught fire adjust the primary air settingsto suit the heat requirements.2. The logs will burn slowly towards the rear ofthe fire chamber and the

Page 3

PRIMARY AIR SETTINGSMAXIMUM - Pull control lever (item 43) all the waytowards the front.LOW (MIN) - Push the control lever (item 43) all theway toward

Page 4

WARNING: USE ONLY CERAMIC GLASS 5mmTHICK. ABUSE SUCH AS STRIKING, SLAMMINGAND USE OF SUBSTITUTE MAT E R I A L SSHOULD BE AVOIDED.FIRE SAFETYTo

Page 5

LEPRECHAUN 90 O.S.A.WOODBURNING STOVEINSTALLATION & OPERATINGINSTRUCTIONSGENERALWhen installing, operating and maintaining yourLeprechaun 90 O.S.A

Page 6

Rear Exit:Fit the heat shield as follows:Screw the four 4” 100mm x 1/4” 6mm tie bolts to theback panel (item 11). Fit the four 1” spacers (item31) ov

Page 7 - EXPLODED VIEW

WARNINGDO NOT OBSTRUCT FREE AIR SUPPLY TO THEAIR INLET DUCT LOCATED AT THE BACK OFTHE STOVE.OUTSIDE AIR CONNECTIONThis stove may be connected direct t

Page 8

7. The chimney system shall comply with the standard for Chimney’s Factory-Built Residential Type and Building Heating Appliances UL 103.8. Any openin

Page 9 - Minimum chimney clearance

Chimney, installed in accordance with the manufac-turers instructions or a lined masonry chimneyacceptable to the authority having jurisdiction.

Page 10

1. Leg2. Ashtray3. Base4. Base Heat Shield5. Combustion Chamber Base Plate6. Fire Door7. Side Panels8. Inside Fire Door9. Door Latch10. Top Side of To

Page 11

THIMBLESThimbles for chimneys or vent connectors should beof fire clay (ASTM C 315, specifications for ClayFlue Linings), galvanised steel of minimum

Page 12 - Fax: 051-302375

between the outer wall of chimney section and shall be 12” (305mm). Chimney section concentric with and spaced 1” (25mm) away from connector by means